Loctite 262 Threadlocker 50ml
Description
262™ is designed for the permanent locking and
sealing of threaded fasteners. The product cures when
confined in the absence of air between close fitting metal
surfaces and prevents loosening and leakage from shock and
vibration. Typical applications include the locking and sealing
of large bolts and studs (up to M25 ). The thixotropic nature of
LOCTITE®
262™ reduces the migration of liquid product after
application to the substrate.
LOCTITE®
262™ is tested to the lot requirements of Military
Specification Mil-S-46163A. Note: This is a regional approval.
Please contact your local Technical Service Center for more
information and clarification
Each lot of adhesive produced in North America is tested to
the general requirements defined in paragraphs 5.1.1 and
5.1.2 and to the Detail Requirements defined in section 5.2.
Registered to NSF Category P1 for use as a sealant where
there is no possibilty of food contact in and around food
processing areas. Note: This is a regional approval. Please
contact your local Technical Service Center for more
information and clarification.
The rate of cure will depend on the substrate used. The graph
below shows the breakaway strength developed with time on
M10 steel nuts and bolts compared to different materials and
tested according to ISO 10964.
The rate of cure will depend on the bondline gap. Gaps in
threaded fasteners depends on thread type, quality and size.
The following graph shows shear strength developed with time
on steel pins and collars at different controlled gaps and tested
according to ISO 10123.
The rate of cure will depend on the temperature. The graph
below shows the breakaway strength developed with time at
different temperatures on M10 steel nuts and bolts and tested
according to ISO 10964.
Where cure speed is unacceptably long, or large gaps are
present, applying activator to the surface will improve cure
speed. The graph below shows the breakaway strength
developed with time on M10 zinc dichromate steel nuts and
bolts using Activator SF 7471™ or SF 7649™ and tested
according to ISO 10964.
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for
compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
LMS dated February-7, 1996. Test reports for each batch are
available for the indicated properties. LMS test reports include
selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
Store product in the unopened container in a dry location.
Storage information may be indicated on the product container
labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than
those previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representative.
Read More
Read Less
Loctite 262 Threadlocker 50ml
- Strength : Medium to High
- Temperature : -65 - 300 °F
- Viscosity : 1200 - 2400 mPa.s (cP) Brookfield
- Key Substrates : Metal: Brass, Metal: Steel, Metal: Steel - Stainless Steel
- Color : Red
- Curing Type : Anaerobic
- Application : Threadlocking
- Resistant to vibration
- Fluoresces to allow quality control and inspection
- Suitable for all metal fasteners
- Med/high strength, general purpose
- Tolerates slight contaminations of industrial oils
- Thixotropic/low viscosity
262™ is designed for the permanent locking and
sealing of threaded fasteners. The product cures when
confined in the absence of air between close fitting metal
surfaces and prevents loosening and leakage from shock and
vibration. Typical applications include the locking and sealing
of large bolts and studs (up to M25 ). The thixotropic nature of
LOCTITE®
262™ reduces the migration of liquid product after
application to the substrate.
Mil-S-46163A
LOCTITE®
262™ is tested to the lot requirements of Military
Specification Mil-S-46163A. Note: This is a regional approval.
Please contact your local Technical Service Center for more
information and clarification
ASTM D5363
Each lot of adhesive produced in North America is tested to
the general requirements defined in paragraphs 5.1.1 and
5.1.2 and to the Detail Requirements defined in section 5.2.
NSF International
Registered to NSF Category P1 for use as a sealant where
there is no possibilty of food contact in and around food
processing areas. Note: This is a regional approval. Please
contact your local Technical Service Center for more
information and clarification.
TYPICAL CURING PERFORMANCE
Cure Speed vs. Substrate
The rate of cure will depend on the substrate used. The graph
below shows the breakaway strength developed with time on
M10 steel nuts and bolts compared to different materials and
tested according to ISO 10964.
Cure Speed vs. Bond Gap
The rate of cure will depend on the bondline gap. Gaps in
threaded fasteners depends on thread type, quality and size.
The following graph shows shear strength developed with time
on steel pins and collars at different controlled gaps and tested
according to ISO 10123.
Cure Speed vs. Temperature
The rate of cure will depend on the temperature. The graph
below shows the breakaway strength developed with time at
different temperatures on M10 steel nuts and bolts and tested
according to ISO 10964.
Cure Speed vs. Activator
Where cure speed is unacceptably long, or large gaps are
present, applying activator to the surface will improve cure
speed. The graph below shows the breakaway strength
developed with time on M10 zinc dichromate steel nuts and
bolts using Activator SF 7471™ or SF 7649™ and tested
according to ISO 10964.
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for
compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
Directions for use:
For Assembly
- For best results, clean all surfaces (external and internal)
with a LOCTITE®
cleaning solvent and allow to dry. - If the material is an inactive metal or the cure speed is
too slow, spray all threads with and allow to dry. - Shake the product thoroughly before use.
- To prevent the product from clogging in the nozzle, do
not allow the tip to touch metal surfaces during
application. - For Thru Holes, apply several drops of the product onto
the bolt at the nut engagement area. - For Blind Holes, apply several drops of the product
down the internal threads to the bottom of the hole. - For Sealing Applications, apply a 360° bead of product
to the leading threads of the male fitting, leaving the first
thread free. Force the material into the threads to
thouroughly fill the voids. For bigger threads and voids,
adjust product amount accordingly and apply a 360°
bead of product on the female threads also. - Assemble and tighten as required.
For Disassembly
- Apply localized heat to nut or bolt to approximately
250 °C. Disassemble while hot.
For Cleanup
- Cured product can be removed with a combination of
soaking in a LOCTITE®
solvent and mechanical
abrasion such as a wire brush.
Loctite Material Specification
LMS dated February-7, 1996. Test reports for each batch are
available for the indicated properties. LMS test reports include
selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
Storage
Store product in the unopened container in a dry location.
Storage information may be indicated on the product container
labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than
those previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representative.
Loctite 262 Threadlocker 50ml
Sale price$28.00
Regular price (/)
Products, Cleaner / Remover và Adhesive / Sealant
Categories
Loctite
Products Brand