Loctite 672 Retaining Compound

0.0

Description

Loctite 672 Low-visc Bearing Mount Retaining Compound 50ml


*Discontinued
  • Strength : Medium
  • Storage Temperature : 46 - 69 °F
  • Viscosity : Low
  • Color : Yellow
  • Curing Type : Anaerobic
  • Application : Retaining
 

LOCTITE 672 is a yellow, fluorescent, methacrylate ester acrylic retaining liquid adhesive designed for the bonding of cylindrical fitting parts. It cures when confined in the absence of air between close fitting metal surfaces and prevents loosening and leakage from shock and vibration. Typical applications include retention of bearings onto shafts and into housings.

  • Fluorescent
  • Allows disassembly for service operations
  • Designed for the bonding of cylindrical fitting parts
LOCTITE®
672™ is designed for the bonding of cylindrical
fitting parts, particularly where disassembly is required for
service operations. The product cures when confined in the
absence of air between close fitting metal surfaces and
prevents loosening and leakage from shock and vibration.
Typical applications include retention of bearings onto shafts
and into housings.
TYPICAL CURING PERFORMANCE

Under normal conditions, the atmospheric moisture initiates the
curing process. Although full functional strength is developed
in a relatively short time, curing continues for at least 24 hours
before full chemical/solvent resistance is developed.
Cure Speed vs. Substrate

The rate of cure will depend on the substrate used. The table
below shows the fixture time achieved on different materials
at 22 °C / 50 % relative humidity. This is defined as the time to
develop a shear strength of 0.1 N/mm².
Cure Speed vs. Bond Gap

The rate of cure will depend on the bondline gap. Thin bond
lines result in high cure speeds, increasing the bond gap will
decrease the rate of cure.
Cure Speed vs. Humidity

The rate of cure will depend on the ambient relative humidity.
The following graph shows the tensile strength developed with
time on Buna N rubber at different levels of humidity.
Cure Speed vs. Activator

Where cure speed is unacceptably long due to large gaps,
applying activator to the surface will improve cure speed.
However, this can reduce ultimate strength of the bond and
therefore testing is recommended to confirm effect.
GENERAL INFORMATION

This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
Directions for use

For Assembly


  1. For best results, clean all surfaces (external and internal)
    with a LOCTITE®
    cleaning solvent and allow to dry.
  2. For Slip Fitted Assemblies, apply adhesive around the
    leading edge of the pin and the inside of the collar and
    use a rotating motion during assembly to ensure good
    coverage.
  3. For Press Fitted Assemblies, apply adhesive thoroughly
    to both bond surfaces and assemble at high press on
    rates.
  4. For Shrink Fitted Assemblies the adhesive should be
    coated onto the pin, the collar should then be heated to
    create sufficient clearance for free assembly.
  5. Parts should not be disturbed until sufficient handling
    strength is achieved.

For Disassembly


  1. Apply localized heat to the assembly to approximately
    250 °C. Disassemble while hot.

For Cleanup


  1. Cured product can be removed with a combination of
    soaking in a LOCTITE®
    solvent and mechanical abrasion
    such as a wire brush.

Loctite Material Specification

LMS dated August-23, 1999. Test reports for each batch are
available for the indicated properties. LMS test reports include
selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
Storage

Store product in the unopened container in a dry location.
Storage information may be indicated on the product container
labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than
those previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representative.